PC-Complete measuring system for hop drying
Art.No.: HYTELOG-HOPFEN
Measuring probe with stainless steel protection tube 150 x 12 mm and 10 m Semoflex-connection cable
specially suitable for the Hop drying kiln, temperature withstanding capacity up to 80 °C (130 °C short time), resin
resistant PE prote
No ratings.
Category:
Hop production
PC-Complete measuring system for hop drying
Measuring probe with stainless steel protection tube 150 x 12 mm and 10 m Semoflex-connection cable specially suitable for the Hop drying kiln, temperature withstanding capacity up to 80 °C (130 °C short time), resin resistant PE protection filter, suitable for stationery assembly in dryer, drying kiln or conditioning chamber, measuring range 0 ... 100% rH and -40 ... +80 °C, integrated impedance measurement (Principle “Wire in Cartridge“), also suitable for band dryers (“Prick“).
Scope of supply: PC-Adapter inclusive of interface connection cable, power supply unit, stainless steel humidity probe with PE-Sinter protection cap and 10 m cable, Windows-Software “RECORDER“ and “PCLOG“
Technical data
Humidity measuring range: 0 ... 100% rH
Humidity resolution: 0.01% rH
Humidity accuracy: ±3% rH (at 23 °C)
Temperature measuring range: –40 ... +80 °C
Temperature resolution: 0.1 °C
Temperature interface resolution: 0.01 °C
Temperature accuracy: ±0.5 °K
Impedance measuring range: approx. 10 kOhm to 1 MOhm
Impedance resolution: 16 Bit, 0 ... 65535 Digits
Impedance accuracy: ±2% of measuring range limits
Response time: 7 seconds
Measuring interval: 7 seconds
Basic instrument operating temperature: 0 ... 80 °C
Interface: RS 232, 4800 Bd, 8N1
Housing dimensions: 151 x 64 x 35 mm
Adapter housing dimensions: 57 x 64 x 35 mm
Housing: Aluminium die-cast, grey
Scope of supply: Measuring probe, PC-cable, mains adapter, operating instructions
Scope of supply: PC-Adapter inclusive of interface connection cable, power supply unit, stainless steel humidity probe with PE-Sinter protection cap and 10 m cable, Windows-Software “RECORDER“ and “PCLOG“
Technical data
Humidity measuring range: 0 ... 100% rH
Humidity resolution: 0.01% rH
Humidity accuracy: ±3% rH (at 23 °C)
Temperature measuring range: –40 ... +80 °C
Temperature resolution: 0.1 °C
Temperature interface resolution: 0.01 °C
Temperature accuracy: ±0.5 °K
Impedance measuring range: approx. 10 kOhm to 1 MOhm
Impedance resolution: 16 Bit, 0 ... 65535 Digits
Impedance accuracy: ±2% of measuring range limits
Response time: 7 seconds
Measuring interval: 7 seconds
Basic instrument operating temperature: 0 ... 80 °C
Interface: RS 232, 4800 Bd, 8N1
Housing dimensions: 151 x 64 x 35 mm
Adapter housing dimensions: 57 x 64 x 35 mm
Housing: Aluminium die-cast, grey
Scope of supply: Measuring probe, PC-cable, mains adapter, operating instructions
Product 4 / 4