- Sensor elements
- Sensor module
- Transducer
- Measurement systems
- Handheld instruments
- Switching devices
- Pressure Dew Point
- Calibration systems
- Distribution Conrad
Most sold
Elektroden pH/Redox
(9)Elektroden pH/Redox
Price worthy pH-Electrode E014
Art.No.: PH-E014
Measuring range of 2 ... 12 pH, application temperature 0 ... 60 °C, conductance > 200 ?S/cm, not pressure resistant, electrolyte 3mol/l KCL, refillable, connection cable 1 m with Chinch-plug.
Standart - pH-Elektrode E100
Art.No.: PH-E100
Measuring range from 0…14 pH, operation temperature 0…80 °C, conductance > 200 S/cm, not pressure-resistant, elektrolyte 3mol/l KCL, refillable, connection cable 1 m with cinch-plug, application areas in environmental analysis, swimmin pool technolgy
Insert-pH-Electrode E101
Art.No.: PH-E101_
Measuring range of 2 ... 11 pH, application temperature 0 ... 60 °C, conductance > 200 ?S/cm, electrode for insertion not pressure resistant, electrolyte 3mol/l KCL, refillable, connection cable 1 m with Chinch-plug.
Twin cells-pH-Electrode E103
Art.No.: PH-E103
Measuring range from 0…14 pH, operation temperature 0…80 °C, conductance > 200 S/cm, not pressure-resistant, elektrolyte 3mol/l KCL, refillable, connection cable 1 m with cinch-plug, application areas are e.g. in the photochemistry
Redox-Electrode E105
Art.No.: PH-E105
Measuring range ± 2000 mV at 0 ... 80 °C, conductance: > 25 ?S/cm, electrolyte 3 mol/l KCL, refillable, scope of supply inclusive of 100 ml test solution, application areas are in the fish keeping, soil examination and laboratory analysis
VE-Water / pH-Electrode E106
Art.No.: PH-E106
Measuring range of 2...11 pH at 10...80 °C, conductivity: > 25 ?S/cm, not pressure resistant, Electrolyte 3 mol/l KCL, refillable, connection cable 1 m with Chinch-plug, application areas are in ion charged media, VE-water and in the fish keeping
Pressure resistant pH-Electrode E108
Art.No.: PH-E108
Pressure resistant up to 6 bar, measuring range of 0 ... 14 pH at 0 ... 80 °C, conductivity: > 200 ?S/cm, Gel Electrolyte not refillable, connection cable 2 m with Chinch-plug, adaptable with thread PG 13,5
Pressure resistant pH-Electrode with Pt100 PH-E109
Art.No.: PH-E109
With integrated Pt100 Sensor element, pressure resistant up to 6 bar, measuring range of 0...14 pH at 0...80 °C, conductance value: > 200 ?S/cm, Gel electrolyte, not refillable, connection cable 2 m with BNC / MiniDIN plug, adaptable without thread
Connection cable with BNC / Banana plug, adaptable with thread PG13.5
Art.No.: PH-E117
With an integrated PT100 sensor element, pressure-resistant up to 6 bar, measuring range 0 ... 14 pH at 0 ... 80 °C, conductance > 25 S/cm, not refillable, application areas in environmental analysis